Fy2112s Direct Digital Synthesis (DDS) Signal Generator 5mhz And Frecuency Counter 60mhz With Usb Con

Brand: FeelTech
Product Code: L030104-FY2112S

Short descriptio


Fy2112s Direct Digital Synthesis (DDS) Signal Generator 5mhz And Frecuency Counter 60mhz With Usb ConFY2112S series direct digital synthesis signal generator use DDS technology and FPGA design with the characters of high... Read more...

Found it Cheaper?
75,02€ Ex Tax: 62,00€

  • Availability: Out Of Stock 0

  • 2 or more 72,02€
  • 10 or more 70,52€
  • 20 or more 66,02€


Fy2112s Direct Digital Synthesis (DDS) Signal Generator 5mhz And Frecuency Counter 60mhz With Usb Con

FY2112S series direct digital synthesis signal generator use DDS technology and FPGA
design with the characters of high stability and low distortion ect.,with the function of TTL output
and 60MHz frequency meter.It can output Sine wave, Square wave (Duty cycle adjustable from
1% to 99%) and Triangle wave (include sawtooth wave). Maximum effective output is greater
than 9Vpp with resolution of 0.01Hz (10mHz). Output amplitude and DC offset can be adjusted
continuously. It has two sweep functions, linear sweep and logarithmic sweep. the start and end
frequency and sweep time can be set at will. It’s the ideal equipment of electronic engineer,
laboratory, production lines, the teaching and scientific research.
It has excellent technical indexes and function features:
◆High frequency accuracy: ±5×10-6
◆High resolution: 10 mHz
◆All range continuously adjustable, digital setting.
◆High waveform accuracy: The output waveform synthesis by calculating function.
◆3.3V TTL electric level output.
◆Several different waveforms: Sine wave, Square wave (Duty cycle adjustable) and Triangle
wave (include sawtooth wave).
◆Sweep function: Linear sweep, Logarithmic sweep. Starting and stop points can be set
optionally.
◆Save function: 10 sets of parameters defined by the users can be saved and loaded anytime.
◆Operation mode: Button controlled, LCD display, digital setting, knob adjusted continuously.
◆Output mode:Standard BNC port output.
◆ Highly reliable : Large scale integrated circuit, Surface mounting technology, reliable and
durable.
◆ Frequency measurement : Frequency of internal / external signal can be measured through
built-in 60MHz frequency meter.

◆ Signal Output function
Output waveforms Sine wave, Square wave (Duty cycle adjustable)
and Triangle wave (include sawtooth wave)
Output amplitude ≥9Vp-p (signal output, no load)(MAX)
≤20mVp-p (MIN)
Output impedance 51Ω±10%(signal output)
DC offset ±2.5V(no load)
Frequency range 0.01Hz ~ 5MHz (FY2112S)
Resolution 0.01Hz(10mHz)
Frequency accuracy ±1×10-6
Frequency Stability ±5×10-6/3 Hours
Sine wave distortion ≤0.8% (reference frequency is 1kHz)
Triangle linearity ≥98% (0.01Hz~10kHz)
Rise and fall time of square wave ≤100ns
Square Wave Duty range 1%~99%(digital control mode)
 TTL Output function
Frequency range 0.01Hz ~ 12MHz (FY2112S)
Amplitude >3Vp-p
Fan Out >20 TTL loads
 COUNTER function
Counter Range 0-4294967295
Frequency Meter Range 1Hz~60MHz
Input Voltage Range 0.5Vp-p~20Vp-p
 SWEEP function
Sweep mode Linear sweep, Logarithmic sweep
Sweep range fM1 to fM2
Sweep time 1s~99s
 Others
Display LCD1602
Save and Load Parameter M0-M9(M0: default load)
Size 200mm(Length)×190mm(Width)×90mm(Height)
Buzzer warning tone Can be turned On/Off by setting
Production technology Surface mounting technology, large scale integrated
circuit, reliable and durable
Operation feature Button-controlled, Knob-adjusted continuously
Conditions requirement Temp: 0~40℃ Humidity: ﹤80%

●Safety Notes
1、Before using this instrument, please check if the power supply is normal, to ensure the
normal use and personal safety.
2、This instrument must be used in the technical index range.
3、Please do not change the instrument circuit arbitrarily, so as to avoid damaging equipment
or endangering the safety.
●Warning and personal injury
Do not apply the product in the safety protection device or emergency stop device, or any
other applications that the product failure could result in personal injury, unless there is special
purpose or use authorization. Before the installation and use, each parameter of the technical
indexes in this manual should be referred to. If this suggestion is not obeyed, death or serious
personal injury could be caused. In this condition the company will not be responsible for any
compensation of personal injury or death, and all the company managers and employees and
auxiliary agents, distributors, other personnel concerned will be released from any claim
(including all the costs, expenses, attorney fees etc.) that may result in.
Appendix
Complete set of instrument and auxiliary
FY2112S DDS function generator / counter----------------1 set
USB Power Supply-------------------------------------------1 pc
Signal output cable---------------------------------------------1 pc
cd with software

Write a review

Note: HTML is not translated!

Tags: fy2112s, direct, digital, synthesis, dds, signal, generator, 5mhz, and, frecuency, counter, 60mhz, with, usb, generators, functions